  Datasheet File OCR Text:
  data sheet ffk? optical differential pressure (flow) transmitter ffi system the model ffk 3 optical differential pressure (flow) transmitter measures differential pressures (flow rates) of various fluids accurately, converts them into optical digital signals and outputs them. this is an intelligent transmitter providing excellent performance and functions due to in- corporation of electrostatic capacitance type silicon sensor and microprocessor. a fiber optical cable used for the signal transmission line forms an optical field instrumentation system together with an optical star coupler and a master station. features 1. resistive to noise and lightning optical signal ensures a reliable signal transmission, be- cause it is not be affected by external noise and induc- tive lightning. use of a nonmetallic optical (fiber) cable prevents propagation of inductive lightning through the cable, so a signal transmission immune to lightning can be realized. 2. reliability due to redundant configuration host system can be duplicated by using two optical cable trunk lines (between an optical star coupler and host system. this enhances reliability of users?systems. 3. intrinsic safety type explosion-proof each equipment with a built-in battery can be constructed so as to be an intrinsic safety type individually (intrinsic safety type barrier unnecessary). specifications functional specifications fluids measured: liquid, gas or steam measuring range and operating pressure: type minimum value maximum value lower range limit upper range limit ffk m 11 ffk m 22 ffk m 23 ffk m 25 ffk m 26 ffk m 33 ffk m 35 ffk m 36 ffk m 38 ffk m 43 ffk m 45 ffk m 46 ffk m 48 operating pressure [mpa] - 0.1 to +3.2 - 0.1 to +10 - 0.1 to +10 - 0.1 to +10 - 0.1 to +10 - 0.1 to +16 - 0.1 to +16 - 0.1 to +16 - 0.1 to +16 - 0.1 to +42 - 0.1 to +42 - 0.1 to +42 - 0.1 to +30 span [kpa] range limits [kpa] 1 6 32 130 500 32 130 500 3000 32 130 500 3000 1 6 32 130 500 32 130 500 3000 32 130 500 3000 - 1 - 6 - 32 - 130 - 500 - 32 - 130 - 500 - 3000 - 32 - 130 - 500 - 3000 0.1 0.15 0.8 3.25 12.5 0.8 3.25 12.5 75 0.8 3.25 12.5 75 date EDS6-125 may 20, 2004
ffk? 2 process temperature, allowable pressure limit: for details refer to fig.1. fill-fluid silicon oil fluorolube oil silicon oil 13th code digit y, g, n w, a, d r process temperature (note) - 40 to +120 c - 20 to +80 c - 15 to +120 c allowable pressure limit 2.7kpa abs atmospheric pressure 2.7kpa abs self-diagnosis: displayed on indication unit (option) and transmitted to master station. diagnosis item host system indication unit measuring range abnormal detecting unit failure amplifier abnormal battery voltage battery voltage low alarm remote control function: see table 1. output signal: optical digital signal power supply: built-in lithium battery (expected life: about 4 years) optical cable: code set type, silica fiber ... core/clad diameter 100/140 m optical connector: fc connector transmission distance: 1.5 km max. (when transmission loss of optical cable is 4 db/km) damping: variable from 0.2 to 32 sec (time constant) zero elevation and suppression: possible within 100% of maximum span. explosion-proof: intrinsic safety type, jis ib iic t3 ambient temperature: - 30 to +70 c - 10 to +60 c for intrinsic safety explo- sion-proof type - 20 to +70 c when provided with indica- tor - 10 to +60 c when filled with fluorolube oil storage temperature: - 40 to +80 c performance specifications for linear output of differential pressure max. span abmient temperature effect url: max. span x : measuring span overrange effect (zero shift at max. span) accuracy rating 1, 6kpa 0.3% / 1mpa 0.1% / 3.2mpa - 0.2% % / 3.2mpa +0.2 - 0.4 +0.2 - 0.4 0.1 % / 10mpa 0.1 % / 16mpa 0.25 % / 42mpa zero shift: twice as large as above when 7th digit (material) is other than v 0.1% when measuring span is 1/10 or more of maximum span. 32, 130kpa 500, 3000kpa low differential pressure medium differential pressure high differential pressure (note) max. span measuring span (0.05 + 0.005 )% when measuring span is less than 1/10 of maximum span. url (0.125+0.2 )% / 28 c x x x x / 28 c overall shift: url (0.175+0.2 )% zero shift: url (0.1+0.05 )% / 28 c / 28 c overall shift: url (0.15+0.05 )% twice as large as above when 7th digit (material) is other than v 3 times as large as above when 7th code (material) is other than v static pressure effect (zero shift at max. span) (span shift at measuring span) 0.2% / 1mpa 0.1% / 3.2mpa - 0.2% % / 10mpa 0.05% / 10mpa twice as large as above when 7th digit (material) is other than v note: percent value with respect to measuring span (including linearity, hysteresis and repeatability in standard 23 c status) for square-root output max. span ambient temperature effect (shift at 20% point) accuracy rating (inclusive of linearity and hysteresis) 1, 6kpa low flow cutoff point flow rate value variable within 0 to 20% (default value: 7%) (between 1 and 0.1) max. span: 0.1% for output 50 to 100% 0.25% for output 20 to less than 50% 0.5% for output 10 to less than 20% (between 0.1 and 0.04) max. span: for output 50 to 100%; for output 20 to less than 50%; for output 10 to less than 20%; max. span max. span max. span 32, 130kpa 500, 3000kpa low differential pressure medium differential pressure high differential pressure measuring span measuring span measuring span 1 (0.05 + 0.005 )% 2.5 (0.05 + 0.005 )% 5 (0.05 + 0.005 )% url 2.5 (0.1 + 0.2 )% / 28 c url x x 2.5 (0.1 + 0.05 )% / 28 c url: max. span x : measuring span
3 inclination effect: 0.12kpa/ 10 double above value when 13th digit (treat- ment, sealed liquid) is w, d, or a. measurement period: 0.2 sec response time: ffk m 11 ffk m 22 ffk mm 3 ffk mm about 0.2 0.8 0.5 0.3 0.2 5 8 type *time constant [sec] dead time [sec] note: *value at 23 c physical specifications material: for details, refer to code symbols. v j h m t b l u scs14 scs14 scs14 scs14 scs14 hastelloy-c lining monel lining tantalum lining sus316l sus316l gold- plated hastelloy-c monel tantalum hastelloy-c monel tantalum sus316 sus316 hastelloy-c monel tantalum hastelloy-c monel tantalum ma- terial code detecting unit operating pressure [mpa] seal diaphragm other wetted parts 3.2 10 16 42 process cover notes: ...available, ...unavailable environmental protection: meets jis c0920 immersion-proof (equivalent to iec ip67 or nema 6/6p). process connection: rc1/4 or 1/4-18npt (whichever selected by code symbol) oval flange thread 7/16-20unf optical cable connection: g1/2 or 1/2-14npt (whichever selected by code symbol) mounting method: mounted on 50a (2b) pipe with u-bolt or on a wall. finish: epoxy-polyurethane double coat, color; silver (blue for case cover). external dimensions: see outline diagram. mass: 5.3 to 5.5kg orientation of transmission unit: indicator unit turnable 90 upward/down- ward relative to detection unit. optional specifications indication unit: 5-digit lcd indication, % or real scale indication (as specified by code symbol) operating temperature range: - 20 to +70 c oxygen oil-proof processing: fluorolube oil filled, wet- ted parts degreased and cleaned. chlorine service: fluorolube oil filled nace specification: h2s-proof treatment in accordance with nace specifications. varies with material. refer to code symbols. ? ? ? ? ? ? ? ? ? ? ?
ffk? 4 table 1 remote control function (items readable and setting from hand-held communicator) item reading setting description maximum range measuring range damping real scale indication battery voltage error indication measured value adjustment maximum measuring range of equipment actual measuring range variable within 0.2 to 32 sec indication in industrial value battery voltage of equipment errors of detection unit and amplifier measured data zero and span adjustment note: for operation of the 3 type transmitter ( 3 at the 8th digit of product code), a hand-held communicator is required to have a version 1.6 or higher, but a communicator before version 1.6 can be operated with memory data updated. (refer to the instruction manual of transmitter.) fig. 1 relation between process temperature and operating pressure 40 60 15 85 120 2.7 4 20 101 [kpa abs] fill-fluid: silicone oil (code: y, g, n) fill-fluid: silicone oil (code: r) operating area none-operating area process temperature [ c] operating pressure system block diagram host system 1 to 5v dc 4 to 20ma dc field equipment (max. 8 units) master station optical fiber type electric converter (type; psn) transmitter star coupler transmitter 1:1 system field control room transmission distance: 1.5 km max. (between master station and field equipment) transmission distance: 4 km max.
5 code symbols connection (4th digit) process connection cable lead-in port rc1/4 g1/2 1/4-18npt 1/2-14npt operating pressure and measuring span (5th and 6th digits) material (7th digit) operating pressure range measuring span - 0.1 to +3.2 mpa 0.1 ...1 kpa - 0.1 to +10 mpa 0.15 6 kpa - 0.1 to +16 mpa 0.8 32kpa 3.25 130kpa 12.5 500kpa 75 3000kpa - 0.1 to +42 mpa 0.8 32kpa 3.25 130kpa 12.5 500kpa - 0.1 to +30 mpa 75 3000kpa - 0.1 to +10 mpa 0.8 32kpa for material codes b, l 3.25 130kpa and u 12.5 500kpa indicator output not provided linear not provided square-root extraction digital, % indication linear digital, real scale linear digital, % indication square-root extraction digital, real scale square-root extraction indicator and output (9th digit) non-explosion proof intrinsic safety, jis explosion-proof (10th digit) ? ? ? f s t 1 2 3 3 3 3 4 4 4 4 2 2 2 1 2 3 5 6 8 3 5 6 8 3 5 6 v j h m t b l u y a l p q s a g ff k 3 description 1 2 3 4 5 6 7 8 9 10 11 12 13 1415 process cover seal other application diaphragm wetted parts (5th and 6th digits) scs14 sus316l sus316 11,22,33,35,36,38, 43,45,46,48 scs14 sus316l gold- sus316 11,22,33,35,36,38, plated 43,45,46,48 scs14 hastelloy-c hastelloy-c 11,22,33,35,36,43, 45,46 scs14 monel monel 33,35,36,43,45,46 scs14 tantalum tantalum 33,35,36 hastelloy-c lining hastelloy-c hastelloy-c monel lining monel monel 23,25,26 tantalum lining tantalum tantalum
ffk 3 6 side vent/drain mounting fixture none none none yes (stainless steel) yes none yes yes (stainless steel) side vent/drain and fixture (11th digit) treatment fill-fluid none silicon oil none fluorolube oil degreasing silicon oil oxygen oil-proof fluorolube oil ... specifiable when 7th digit is v. processing chlorine service fluorolube oil ... cannot be specified when 7th digit is v, m or l. nace specification fluorolube oil ... cannot be specified when 7th digit is t or u. none silicon oil (for vacuum) viton teflon treatment and fill-fluid (13th digit) o-ring material (for process cover)(14th digit) nace bolt/nut (astm a193 b7m/a194 2hm) nace bolt/nut (astm a320 l7m/a194 2hm) sus304/sus304 ... (for general use) ... note 2 sus630/sus304 ... specify when 5th digit is 3 or 4. bolt/nut (15th digit) note 1 ? ? ? cannot be specified when 7th digit is b, l or u. ? ? ? a c d f y w g a d n r a b c d e f note 1: operating pressure is limited within 10 mpa. note 2: specifiable when 5th digit is 1, 2 or 3. however, operating pressure is limited within 10 mpa. f fk 3 f description 12345678 910111213 1415
7 details of b details of a indicator (option) 315 ffks d e rc1/4 g1/2 1/4 18npt 1/2 14npt type ffkt 70 108 241 p 80 8 70 225 15 102 mounting pipe jis 50a (2b) u-bolt (m8) 37 27 47 gas vent, drain port 54 41.3 27 lh view from arrow p a high pressure connection a low pressure connection 4 7/16-20unf thread depth 13 (for oval flange) 15 7 18.5 e d 15 3 2.5 8 b optical cable lead-in port details of a s t ffk 3 a c b l u a pressure connection gas vent, drain port 4-7/16-20unf thread depth 10 (for oval flange) 28 41.3 40 54 102 318 47 27 4 1 2 0 0.1 16 12 +0.2 +0.1 s t ffk 3 a c v j h m t outline diagram (unit : mm)
ffk 3 scope of delivery instrument body and pipe fixture (as specified) item to be prepared separately oval flange: to be used as a flange of connecting pipe port. for details, refer to the data sheet of oval flange (eds6-10). equalizing valve: refer to data sheet (eds6-10). ordering information 1. model type 2. measuring range 3. indication scale for real scale specification 4. others information in this catalog is subject to change without notice. printed in japan head office 6-17, sanbancho, chiyoda-ku, tokyo 102-0075, japan http://www.fesys.co.jp/eng sales div. international sales dept. no.1, fuji-machi, hino-city, tokyo, 191-8502 japan phone: 81-42-585-6201, 6202 fax: 81-42-585-6187 http: //www.fic-net.jp/eng caution on safety *before using this product, be sure to read its instruction manual in advance.


▲Up To Search▲   

 